top of page
Norsecraft-TEC-Logo-top (1).jpg
L-Castor-Drilling-Solution.png
JackUp-Logo.png

JACKUP-LUBE

LESS FRICTION. MORE PROTECTION

Saudi_Aramco_Rigs_in_the_Hasbah_Field03.650770a1b9343.650b83f15c410.avif

ENGINEERED FOR JACK-UP OPERATIONS

Protect the Jacking System Before Damage Escalates

JackUp-Lube combines controlled lubrication, thermal monitoring, visual surveillance and system alarms to support safer and more reliable jacking operations.

RISK REDUCTION

RELIABILTY

HSE

INTRODUCING JACKUP-LUBE / 02

A controlled approach.
A safer operation.

A safer, more controlled and documented approach to rack-and-pinion lubrication.

Crossway-Eagle_01_Q40 (1).jpg

A critical interface.
A traditionally manual task

THE INDUSTRY CHALLENGE / 03

The Real Cost of Jacking System Failure

A local problem can become a major operational event.

Jacking-system failures can escalate from pinion damage to structural repair, evacuation, off-hire and contract disruption. The consequences extend well beyond the damaged component.

01

Mechanical damage

Wear at the rack-and-pinion interface can develop into a wider repair scope.

02
 

Operational interruption

Inspection, specialist engineering and replacement work affect rig readiness.

03

Commercial exposure

Downtime can affect schedules, dayrate revenue and customer contracts.

HSE & PERSONELL EXPOSURE / 04

Reduce Personnel Exposure During Jacking Operations

Move lubrication out of the line of fire.

Manual lubrication places personnel close to rack teeth, pinions and moving machinery. Automation can reduce the need for direct intervention while retaining control of the lubrication process.

Moving machinery

Less manual activity near pinch points and rotating equipment.

Access conditions

Reduce tasks at elevated or difficult-access locations.

Offshore conditions

Reduce dependence on manual work in adverse weather.

Process consistency

A repeatable process across crews, shifts and jacking cycles.

Manual Lubrication.png

An additional engineering control supporting existing safety procedures.

THE FAILURE CHAIN / 05

Intervene before
the damage escalates.

Controlled lubrication and monitoring create earlier opportunities to identify a developing problem.

01

Lubrication
Deficiency

02

Rising
Friction

03

Accelerated
Wear

04

Pinion / Rack
Damage

05

Downtime
and Repair

JackUp-Lube acts early: improve lubrication, detect abnormal conditions and alert the crew before a developing problem propagates.

THE JACKUP - LUBE SOLUTION / 06

More Than Automated Lubrication

Lubrication becomes part of the jacking process.

JackUp-Lube supplies lubricant continuously and accurately to the rack-and-pinion contact while the asset is being raised or lowered. Configuration and lubricant volume are adapted to the asset.

01 / INITIATE

Start with the operation

Automatic start/stop or operator command.

02 / DELIVER

Control the supply

Centralized pumping and pressure-based delivery.

03 / APPLY

Reach the contact

Metered application at defined lubrication points.

The Solution.jpg

CONTROLLED APPLICATION

RACK & PINION

Operational Benefit.jpg

CONTROL & MONITORING / 07

Monitoring, Control and Documentation

A defined process. A clearer operational picture.

Monitor the lubrication system from the control room. Pressure, pump operation, lubricant level, faults, cycles and consumption can be monitored and logged, depending on the configuration.

Thermal and visual surveillance help operators investigate abnormal conditions. System alarms highlight delivery faults that could otherwise go unnoticed.

Pressure

Pump status

Grease level

System alarms

Operating cycles

FOUR LAYERS OF RISK REDUCTION / 08

Control. Observe. Respond.

The Solution.jpg

01

Controlled Lubrication

Consistent application at the rack-and-pinion contact reduces dependence on manual coverage.

Data Analytics Screen

02

Thermal Monitoring

Abnormal local heat can be an early warning of friction or loading that needs investigation.

Bilde2.png

03

Camera Monitoring

Operators can visually monitor the pinions from the control room during the operation.

Analyzing Stock Data

04

System Health Alarms

Identify delivery faults, nozzle issues and grease-supply status to support an earlier response.

JACKING SYSTEM PROTECTION / 09

Critical jacking operations.
Major repair challenges.
Better protection.

Failure in a jack-up’s jacking system can have serious safety and financial consequences. Repairing or replacing gears, pinions and racks can require extensive engineering, specialized lifting equipment and complex offshore / onshore work.

01

Even when downtime is avoided, the repair effort can be substantial.

DNV has also highlighted the industry’s challenges through projects addressing maintenance, inspection and wear assessment. Its publications describe how intermittent operation, changes in onboard expertise and the complexity of assessing wear can make reliable maintenance difficult. They emphasize competent personnel, clear inspection routines and accurate maintenance records.

02

JackUp-Lube combines controlled lubrication with monitoring during jacking.

Automatic grease delivery to the loaded pinion tooth flanks is synchronized with the jacking operation. Temperature sensors, cameras and system alarms give the crew better visibility of operating conditions and help identify abnormal temperature developments and system deviations requiring attention.

By combining lubrication with monitoring, JackUp-Lube helps reduce friction and wear while supporting earlier detection and timely intervention. The aim is to reduce the risk of damage to gearboxes, bearings, pinions and racks and support more reliable jacking operations, alongside established inspection and maintenance procedures.

JackUp-Lube’s patent application is currently under examination.

We are also in dialogue with classification societies and insurers, seeking their assessment and recommendations on how the combined lubrication and monitoring system can help reduce the risk of damage to jacking equipment. This process is ongoing.

THE BUSINESS CASE / 10

A single jacking-system incident can cost several times more than the investment in prevention.

INDICATIVE SYSTEM INVESTMENT

~ 10 days

of a USD 125k/day public rig dayrate equals
the current indicative JackUp-Lube system

price.

30 DAYS OFF DAYRATE

USD 3.75m

Illustrative gross dayrate exposure for 30 days at USD 125k/day.

90 DAYS OFF DAYRATE

USD 11.25m

Illustrative gross dayrate exposure for 90 days at USD 125k/day.

Illustrative comparison only. Dayrate exposure is not net financial loss or a guaranteed saving. Actual impact depends on contract terms, repairs, insurance and operational circumstances. JackUp-Lube cannot guarantee prevention of every failure, including sudden overload, material defects or failures without a detectable precursor.

INSTALLED SYSTEM / 11

JackUp-Lube in Operation

Real installation. Real operation.
See the system where it works.

ENGINEREED CONTAINER SOLUTION / 12

Complete
Containerized System

Delivered as a fully integrated solution ready for installation and commissioning.

Asset-specific engineering

01

Integrated system delivery

02
 

Installation & commissioning

03

Container med JackUp-Lube klar for shipping.png
Crossway-Eagle_01_Q40 (1).jpg

ABOUT JACKUP-LUBE / 13

Developed for Real
Jack-Up Operations

Offshore experience. Applied to a critical task.

JackUp-Lube is developed by Norsecraft Tec in cooperation with Castor Drilling Solution. The system brings centralized lubrication into the jacking process, with configuration adapted to each asset.

Developed by Castor Drilling Solution and Norsecraft Tec.

For nearly 50 years, Norsecraft Tec has supplied centralized lubrication systems offshore, from engineering and production to installation, commissioning and service.

Castor Drilling Solution equipment and offshore engineering company founded in 2011 by a team of technical experts with extensive experience from the offshore drilling systems industry.

Applications include Oil & Gas jack-up rigs, wind turbine installation vessels, accommodation, service and decommissioning jack-ups.

Engineering, installation, commissioning and service.

jonathan-gong-EqFU9IjTBQQ-unsplash.jpg

Let’s discuss your operation.

I would like to

TAKE THE NEXT STEP / 14

Prevent what can be prevented.
Detect what can be detected.
Act before damage escalates.

Start with a technical conversation about your asset.

Skuiveien 43, 1339 Vøyenenga, Norway

bottom of page